5 citations
,
February 2014 in “Journal of Liquid Chromatography & Related Technologies” Method accurately measures finasteride and tamsulosin in combined drug form.
29 citations
,
June 2017 in “Journal of Inherited Metabolic Disease” High-content screening is useful for finding new treatments for rare diseases and has led to FDA-approved drugs.
17 citations
,
May 1997 in “Journal of Chromatography B: Biomedical Sciences and Applications” Method accurately measures finasteride in human plasma.
January 2024 in “International Journal of Biological and Environmental Investigations” A reliable method was developed to measure dutasteride in tablets accurately and consistently.
Researchers developed a method to identify and measure different animal hair fibers in textiles, successfully distinguishing materials like cashmere from cheaper fibers.
August 2025 in “İstanbul Gelişim Üniversitesi Sağlık Bilimleri Dergisi” The method accurately measures vitamin E compounds in capsules.
January 1990 in “Medical Entomology and Zoology” A new method can quickly detect alcohol abuse by analyzing hair in under an hour.
January 2005 in “Fuzhou daxue xuebao. Ziran kexue ban” The method is quick and effective for testing steroid 5 alpha-reductase inhibitors.
17 citations
,
August 2015 in “Journal of steroid biochemistry and molecular biology/The Journal of steroid biochemistry and molecular biology” The study found that urine metabolites M1b or M4 are the best indicators of ATD use in horses, with detection possible up to 77 hours in urine and 28 hours in blood.
1 citations
,
November 2025 in “Clinical Chemistry and Laboratory Medicine (CCLM)” The study developed an isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for quantifying dehydroepiandrosterone sulfate (DHEAS) in human serum and plasma, addressing the limitations of current immunoassays. The RMP demonstrated high selectivity, sensitivity, and matrix-independence, with a measurement range of 0.800 to 8,400 ng/mL. The method showed no statistically significant bias, with relative biases ranging from -1.9 to 3.6% across different sample types. Measurement uncertainties were within acceptable limits, expanding to 7.9-11.1% for low ranges and 7.1-8.3% for high ranges at a 95% confidence level. The RMP's high analytical performance and ability to differentiate DHEAS from other androgens make it suitable for routine assay standardization and clinical sample evaluation.
2 citations
,
June 2003 in “PubMed” The two finasteride formulations are bioequivalent.
823 citations
,
February 1998 in “Analytical Chemistry” Method detects finasteride in plasma at very low concentrations.
6 citations
,
February 2022 in “European journal of endocrinology” The method can measure multiple hormones in women's hair and may help identify hormone-related health issues.
January 2005 in “Yaowu fenxi zazhi” The method accurately measures finasteride in human plasma quickly and reliably.
15 citations
,
November 2006 in “Journal of Pharmaceutical and Biomedical Analysis” Method measures finasteride in plasma, suitable for pharmacokinetic studies.
13 citations
,
March 2019 in “PLoS ONE” A new method improves protein analysis in hair, aiding health and disease research.
7 citations
,
September 2014 in “Mass spectrometry letters” The best method to monitor dutasteride in rat plasma is liquid-liquid extraction with methyl tert-butyl ether and methylene chloride.
18 citations
,
March 2010 in “Therapeutic Drug Monitoring” A new method quickly detects alcohol use from hair in under an hour.
1 citations
,
July 2023 in “International Journal of Pharmaceutical Sciences and Drug Research” The HPTLC method is effective and accurate for measuring linoleic and oleanolic acid in Eclipta alba.
12 citations
,
August 2016 in “Biomedical Chromatography” A new method accurately measures clobetasol propionate in hair and skin.
2 citations
,
December 2019 in “Bioanalysis” Accurate quantitative bioanalysis using LC-MS/MS is challenging due to matrix effects, but using internal standards and new methods like in-sample calibration could improve results.
4 citations
,
January 1993 in “Clinical Chemistry and Laboratory Medicine (CCLM)” The new method is 1000 times more sensitive for measuring hair growth.
February 2021 in “European Chemical Bulletin” A reliable method was developed to measure Minoxidil and Finasteride accurately in medicines.
2 citations
,
January 2012 in “Journal of The Chilean Chemical Society” New method accurately measures finasteride in tablets and bulk.
4 citations
,
May 2020 in “Medicine in Drug Discovery” The study developed a method to detect minoxidil and its sulfate form, found that minoxidil sulfate is temperature-sensitive, and identified a way to potentially increase its stability for hair loss treatment.
May 2019 in “Clinica chimica acta” The study developed methods to measure biomarkers in mice and found differences in hormone levels linked to gut microbiota diversity and stress response.
1 citations
,
December 2009 in “Asian Journal of Research in Chemistry” The methods accurately measure Finasteride and Tamsulosin in tablets.
January 2025 in “Current Trends in Pharmacy and Pharmaceutical Chemistry” New methods for measuring dutasteride are effective and reliable.
December 2023 in “International Journal of Advanced Research in Science, Communication and Technology” A reliable method was created to measure Minoxidil and Finasteride in a solution.
4 citations
,
May 2024 in “Steroids” The method accurately measures sex hormones in human plasma but can have small errors.